ISSN : 2663-2187

Significance of Elevated LA1c/c Hb1peak in a HbA1c chromatogram: A delimma

Main Article Content

Dr Amita K Gadhok, Dr Poonam sahni, Dr Parul Singla, Dr Naveen Singh
» doi: 10.48047/AFJBS.6.14.2024.4370-4379

Abstract

Background and objective: In HbA1c estimation by HPLC method Labile A1c fraction is formed which is unstable and its concentration varies with acute changes in plasma glucose levels. Elevated peak of LA1c/Chb-1 may be due to variation in plasma glucose levels or elution of Hbf in labile A1c fraction indicating hemoglobin disorder. Methods: HbA1c is estimated in our laboratory by HPLC method on BIORAD D-10 system which is an automated cation exchange HPLC instrument. Results: Our study focused on a patient's abnormal chromatogram showing abnormal high peak of LA1c/cHb-1 along with missed Hbf in HbA1c estimation and after eliminating preanalytical error patient’s report was released with comment on possibility of hemoglobionopathy. Conclusion: Advantage of HbA1c estimation with HPLC method is to identify hemoglobinopathy can only be achieved by properly analyzing the chromatogram of each and every patient by expert technician or doctor available.

Article Details